|HGH20 Series · 20 mm Profile Rail · Square Flanged Block
HGH20
|
01 / Five figures on the table, two on the quotationOne of Them Is a Moment

Ratings as published for HGH20CA. The 50 km basis is the ball-series definition: C(50 km) = 1.26 × C(100 km), so this same block, if re-quoted on a 100 km basis, would carry 21.5 kN. That is why a C figure means nothing until the basis is stated - and why a ball-series C should never be compared directly with a roller-series one.

02 /Moment is a force with a lever1 kN Reaches the Rating at 270 mm

Applied moment is M = F · e - the force multiplied by the height or offset at which it acts. Nothing in that expression is about size: a small force on a long lever is the same moment as a large force on a short one, and the guide cannot tell the difference.
A 1 kN force - 2.7% of the static rating - hits the full roll moment at a 270 mm offset, and the full pitch or yaw moment at 200 mm. Apply the static safety factor of two that most machine builders use, and those offsets halve: 135 mm and 100 mm. Any bracket, spindle nose or gripper that stands further out than that is being selected on a rating nobody calculated.
The 3 kN at 200 mm in the header is 0.60 kN·m - 2.2 times the roll rating, with a radial load at 8.2% of C0. That is not a marginal design; it is a design that has already failed the check it never ran.
One honest caveat about the numbers: the two HIWIN pages that publish
these moments differ on the pitch and yaw value (0.20 against 0.28 kN·m).
The larger figure would put the two axes above the roll axis, which the symmetric
block geometry does not support, so this page uses the 0.27 / 0.20 / 0.20 set -
and would rather say so than quietly pick one.
03 /The couple divides by the spacing240 mm of Rail Is Worth 35 Times the Life

Two blocks on one rail resist a moment as a couple: one end pushes down by M / s, the other pulls up by the same amount, where s is the distance between them. Add the direct share of the force and the most heavily loaded block carries F/2 + M/s.
That division is the whole design lever. The same 3 kN force at the same 200 mm offset gives 11.5 kN per block if the blocks sit 60 mm apart, and 3.5 kN if they sit 300 mm apart. The rail, the block, the preload and the accuracy grade are identical in both cases; only 240 mm of rail length changed.
The consequence is not academic. At 0.5 m/s for eight hours - 14.4 km a day - the 60 mm arrangement is due for replacement in about two weeks, and the 300 mm arrangement in about sixteen months. This is also the honest answer to the recurring question of whether one long block beats two short ones: a long block raises the moment rating by about 30%, a wider spacing divides the reaction by three or four. Spacing wins every time it is physically available.

04 / Which check actually rejects the design
The Static Check Passes. The Machine Still Fails.
Run the table above through the static check and every row passes
comfortably: 11.5 kN against C0 36.68 kN is a factor of 3.2, which clears
even the machine-tool end of the usual range. Nothing here looks like
an overload.
But the life column spans 194 to 6 877 km - a factor of 35 - and that is the check the static factor cannot see. Static ratings ask whether the groove takes a permanent set today; life asks how many kilometres the surface survives. A design can pass the first with a wide margin and be in the second for two weeks.
There is a mirror-image mistake at the other end of the range. At a genuinely light load - 1 kN per block - the formula returns 295 000 km, some 56 years of continuous running. Life has stopped being the limiter, and what actually ends the block's service is contamination, lubrication interval and rail straightness. Below about 2 kN per block, spend the effort on seals and wipers rather than on a larger size.

05 / The other two columns
Grade and Preload Change Nothing in the Rating

Accuracy grade and preload class are printed in the same part number and are often read as if they were strength options. They are not. C, C0 and M0 are identical across every grade and every preload class of the same block - the numbers in section 01 apply to all of them.
What the grade changes is the geometry of the assembly once it is on your machine: running parallelism of the block to the rail, and the variation of that parallelism along the stroke. Accuracy is bought for the part you are making, not for the load you are carrying.
What the preload changes is stiffness and lost motion - and it works the same way it does in a ball nut: heavier preload removes clearance and raises rigidity, and spends light-load life to do it. The one thing it does not do is raise the moment rating.

06 /The 20 frame, four ways
Long Block or Wide Flange

All four run on the same 20 mm rail: rail width 20 mm, rail height 17.5 mm, hole pitch 60 mm, bolt M5 × 16, rail mass 2.21 kg/m. Block mounting is tapped M5 × 6 deep, bolt pattern B 32 mm, C 36 mm; block height 30 mm. Block and rail are GCr15 (SUJ2) bearing steel, induction hardened. Dynamic loads are the HG series table values on the 50 km basis; moments in kN·m.


07 / FAQ
The Questions the Load Column Does Not Answer
Q:Is C = 27.1 kN the load my carriage can carry?
A:No. It is the load at which 90% of identical blocks reach 50 km of travel, and even that is defined for a pure radial load with no moment. Your carriage carries a force and a moment at once; the block load that matters is F/2 + M/s for two blocks, and that number - not C - is what goes into the life calculation.
Q: What exactly is a moment rating, in kN·m?
A:It is the static moment that produces the same permanent deformation as the static load rating - one ten-thousandth of the ball diameter - applied about one of the three axes: roll along the rail, pitch and yaw across it. For HGH20CA that is 0.27 for roll and 0.20 for pitch and yaw. Compare the applied moment with these directly, after dividing by your safety factor.
Q:Do I need two blocks per rail?
A:If the load has any offset from the rail axis, yes. A single block can only resist a moment through its own ball rows, so the whole moment lands inside one block and is limited by its 0.27 kN·m rather than by any spacing. Two blocks, even closely spaced, convert the moment into a couple the rail can help carry.
Q: How much spacing do I need?
A:Two conditions, checked in this order: the block load F/2 + M/s must stay under C0 divided by your static safety factor, and the life at that block load must cover the kilometres you expect. In practice the spacing that satisfies both is often larger than the one drawn - and since it costs rail length rather than a bigger size, it is the cheapest correction available.
Q:Is the long block (HA) worth the lost travel?
A:It adds 20.7% to C, 29.6% to the roll moment, and 14.7 mm of length per block - about 29 mm of stroke on a two-block carriage. Worth it when the moment is the limiting check and the stroke has margin; not worth it when the stroke is tight, because the spacing correction would have given more for less.
Q:Does a higher accuracy grade or heavier preload raise the load rating?
A:No. C, C0 and the three moments are the same for every grade and preload class of the same block. Grade changes running parallelism and the consistency of it along the stroke; preload changes stiffness and lost motion. Both are worth paying for, neither is a strength upgrade.

Send the Offset and the Spacing. Get the Block Load.
Tell us the force, how far it sits from the rail axis, the spacing between blocks and the kilometres you expect per year. The quotation will come back with the block load, the static factor and the life it implies - and with the grade and preload matched to what the axis actually has to do.
Hot Tags: hgh20 linear guide, China hgh20 linear guide manufacturers, suppliers, factory, linear guide exhibition, Linear Guides for CNC Machine Tools, Long Travel Linear Guide Blocks, Miniature Linear Guide Blocks, Precision Linear Guides for Laser Equipment, stiffness testing of linear guide